6SL3325-1TE35-0AA3 SIEMENS SINAMICS S120
SINAMICS S120 SINGLE MOTOR MODULES INPUT: 600 V DC OUTPUT: 3-PH 400 V, 490 A FRAME SIZE: CHASSIS LIQUID COOLING SUPPORT OF EXTENDED SAFETY INTEGRATED FUNCTIONS
This website uses cookies to ensure you get the best experience on our website. More info |
|
Rashad Al-Zamily
Qatar - Doha
Ordered online, delivered a day early which was great. Highly recommend to anyone looking for a company that makes good on their promise of customer satisfaction!
18/10/19
Gary M.
Scotland - Glasgow
Excellent customer service! Mr Emmanuele call with me and inform me. Good information. All is good. Very seriously. Thank You
13/09/19
Gustavo Ortega
Los ejecutivos tienen buena disposiciòn para ayudar es por eso que recomiendo 100% a Wiautomation, seriedad y responsabilidad.
26/08/19
Eric Boden
They helped me find electronic products for the naval sector, these products have now been discontinued for many years. Thank you, see you soon
23/08/19
Miley Smith - EWA Purchasing Dept.
Our company have a partnership with them from a long time because we always have a great shopping experience from start till the end
20/08/19
Costantino Del Gado
Pannelli sigillati e consegnati come da previsione. Consiglio questo sito, sia per i prezzi che per il catalogo prodotti.
17/08/19
Emmanuele Aprea
Inverter Fanuc ricevuto anche prima dei termini previsiti. Grazie
14/08/19
Liam Gibbs
Everything was perfect, technical assistance, purchase advice, products and delivery.Thanks a lot
12/08/19
Francesco Di Bella
Spedizione in ritardo di un giorno.
11/08/19
Jalil Okeke
A great help
01/08/19
Antonio Marsala
Tutto ok. Grazie
25/07/19
Noah S.
They help us to provide all requested products. Many thanks to Fulvio
25/07/19
Berry Owen
For discontinued products it is truly the best supplier with super-fast deliveries
24/07/19
Ing. Donati
Consegna rapida
22/07/19
Marla Dully
Part delivered on time as promised. Impressed. Will order again.
18/07/19
Marta Rezzoli
La nostra azienda è al quarto acquisto di prodotti Siemens da wiautomation, senza aver mai avuto un problema. Se avessimo conosciuto questo sito prima, avremmo certamente evitato spiacevoli situazioni causate da altri siti web dello stesso settore. Grazie
18/07/19
Mattia Rossi
Tutto perfetto, se vogliamo trovare una pecca ? stata la consegna con ritardo un giorno.
16/07/19
Carol Moates
Great company to deal with, super fast replies. Very helpful and friendly!
15/07/19
Ingrid Freeman
Very fast delivery!
12/07/19
Monroe Clark
We needed to replace 3 faulty inverters, we bought on this site for the first time and we really enjoyed our time with Vanessa who followed us through the entire process until delivery. Thank you
06/07/19
SINAMICS S120 SINGLE MOTOR MODULES INPUT: 600 V DC OUTPUT: 3-PH 400 V, 490 A FRAME SIZE: CHASSIS LIQUID COOLING SUPPORT OF EXTENDED SAFETY INTEGRATED FUNCTIONS
SINAMICS S120 SINGLE MOTOR MODULES INPUT: 600 V DC OUTPUT: 3-PH 400 V, 310 A FRAME SIZE: CHASSIS LIQUID COOLING SUPPORT OF EXTENDED SAFETY INTEGRATED FUNCTIONS
SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu: 1600 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 1000 A, Ie at AC-23 A at 690 V: 800 A, screw mounting, motorized operating mechanism, at the right end, long handle, busbar connection
circuit breaker VL1600 UL; type PG (cat no. LPX3B160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40°C In=< 1600A, rated current II=7000...12000A short-circuit protection IR=1600A ETU for line protection without...
circuit breaker VL1600 UL type PG (cat no. LPX3K160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit...
circuit breaker VL1600 UL type PG (cat no. LPX3G160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection...
circuit breaker VL1600 UL type PG (cat no. LPX3A160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A...
circuit breaker VL1600 UL type PG (cat no. LPX3K120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit...
circuit breaker VL1600 UL type PG (cat no. LPX3G120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection...
circuit breaker VL1600 UL; type PG (cat no. LPX3B140) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40°C In=< 1400A, rated current II=7000...12000A short-circuit protection IR=1400A ETU for line protection without...
circuit breaker VL1600 UL type PG (cat no. HPX3K160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection...
circuit breaker VL1600 UL type PG (cat no. HPX3G160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A...
circuit breaker VL1600 UL type PG (cat no. LPX3A120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A...
circuit breaker VL1600 UL type PG (cat no. HPX3K120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection...
circuit breaker VL1600 UL type PG (cat no. HPX3G120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A...
SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu: 1250 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 1000 A, Ie at AC-23 A at 690 V: 800 A, screw mounting, motorized operating mechanism, at the right end, long handle, busbar connection
circuit breaker VL1600 UL type PG (cat no. HPX3A160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A overcurrent...
circuit breaker VL1600 UL; type PG (cat no. LPX3V160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.5 to 8xIR, II=6 xIn short-circuit protection IR=700-1600A...
circuit breaker VL1600 UL type PG (cat no. HPX3A120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole; NEMA rating 65kA/480V and 35kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A overcurrent...
circuit breaker VL1600 UL; type PG (cat no. LPX3B120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40°C In=< 1200A, rated current II=7000...12000A short-circuit protection IR=1200A ETU for line protection without...
circuit breaker VL1600L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch
circuit breaker VL1600 UL type PG (cat no. NPX3K160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit...
circuit breaker VL1600 UL type PG (cat no. NPX3G160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection...
circuit breaker VL1600L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch
circuit breaker VL1600L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected with ground-fault protection without auxiliary release without auxiliary/alarm switch
circuit breaker VL1600 UL type PG (cat no. NPX3K120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit...
circuit breaker VL1600 UL type PG (cat no. NPX3G120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection...
circuit breaker VL1600 UL; type PG (cat no. LPX3W160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40°C 3 phases/4 lines In=1600A, rated current II=1.25 to 6 xIn, short-circuit protection IR=700-1600A overcurrent rel....
circuit breaker VL1600L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch
circuit breaker VL1600 UL; type PG (cat no. HPX3V160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40°C 3 phases/4 lines In=1600A, rated current ISD=1.5 to 8 xIR, II=6 xIN short-circuit protection IR=700-1600A overcurrent...
circuit breaker VL1600 UL type PG (cat no. NPX3A160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1600A, rated current ISD=1.25-10xIR, II=6xIN short-circuit protection IR=700-1600A...
circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch
circuit breaker VL1600 UL type PG (cat no. NPX3A120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 standard breaking capacity 3-pole; NEMA rating 35kA/480V and 25kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A...
circuit breaker VL1600 UL; type PG (cat no. LPX3V120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LSIG TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.5 to 10xIR, II=10xIn short-circuit protection IR=700-1200A...
circuit breaker VL1600L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch
circuit breaker VL1600 UL; type PG (cat no. HPX3B160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit TM, LI TA=40°C In=< 1600A, rated current II=7000...12000A short-circuit protection IR=1600A ETU for line protection without connection...
circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch
circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected with ground-fault protection without auxiliary release without auxiliary/alarm switch
circuit breaker VL1200 UL type NG (cat no. LNX3K120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG-G with alarm TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit...
circuit breaker VL1200 UL type NG (cat no. LNX3G120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LSIG TA=40°C 3 phases/4 lines In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection...
SENTRON, ATE, transfer switching equipment 3KC, automatically, ATSE, 4- pole, Iu: 1000 A, Ue AC: 415 V, Ie at AC-33 B at 415 V: 800 A, Ie at AC-23 A at 690 V: 630 A, screw mounting, motorized operating mechanism, at the right end, long handle, busbar connection
circuit breaker VL1250L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=1250A, rated current IR=500...1250A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch
circuit breaker VL1250L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit LCD ETU42, LSIG In=1250A, rated current IR=500...1250A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected with ground-fault protection without auxiliary release without auxiliary/alarm switch
circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch
circuit breaker VL1600 UL; type PG (cat no. HPX3W160) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40°C 3 phases/4 lines In=1600A, rated current II=1.25 to 6 xIN, short-circuit protection IR=700-1600A overcurrent rel. for...
circuit breaker VL1200 UL type NG (cat no. LNX3A120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole; NEMA rating 100kA/480V and 65kA/600V (molded case circuit breaker) trip unit LCD ETU, LI/LS/LSI TA=40°C In=1200A, rated current ISD=1.25-10xIR, II=10xIN short-circuit protection IR=400-1200A...
circuit breaker VL1250L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1250A, rated current IR=500...1250A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch
circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch
circuit breaker VL1600N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU22, LSIG In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8 xIR, II=9 xIN short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch
circuit breaker VL1600 UL; type PG (cat no. LPX3W120) non-interchangeable frame, with circuit breaker approval acc. to UL 489 very high breaking capacity 3-pole, NEMA rating 100kA/480V, (molded case circuit breaker) trip unit ETU, LIG TA=40°C 3 phases/4 lines In=1200A, rated current II=1.25 to 10xIn, short-circuit protection IR=400-1200A overcurrent rel....